Emergency measures for hydraulic pliers-hydraulic tools

1, when the pressure loss, the first contact with the furnace before the ban on all cylinder body, and then shut down the liquid according to the rules of the liquid, deal with related matters.
2, when a power outage, notify the stove, and then close all valves hydraulic clamp pressure is not in place, there is no strength how to do

3, the amount of oil is not enough, not enough fuel.
4, check the hydraulic oil pollution and mixed with impurities, when the oil mixed with impurities, often in the oil inlet caused by steel ball and arc cylinder seal is not strict, not up to the pressure of demand. The solution, oil, cleaning oil.
5, such as cleaning and changing is not enough pressure, adjustable pressure valve, high pressure valve will sometimes loose, so that the hydraulic pressure did not reach the required clamp start pressure relief.
6, if the pressure regulating valve to adjust the pressure of demand also, need to consider the cylinder ball wear, spring weak or broken, oil pressure piston wear, seal failure and cylinder wear, etc.. At this ti